CLCKH - E90G203, CHROMATED EPOXY POLYAMIDE PRIMER PART A (P&L 72450)

  • MSDS: CLCKH
  • Manufacturer: SHERWIN WILLIAMS
  • Product Name: E90G203, CHROMATED EPOXY POLYAMIDE PRIMER PART A (P&L 72450)
  • National Stock Number: 8010-01-312-1169
Product Identification

Product ID:E90G203, CHROMATED EPOXY POLYAMIDE PRIMER PART A (P&L 72450)
MSDS Date:12/17/1997
FSC:8010
NIIN:01-312-1169
Status Code:A
Kit Part:Y
MSDS Number: CLCKH

Responsible Party
SHERWIN-WILLIAMS
630 E 13TH ST
ANDOVER, KS 67002
US

Emergency Phone: 216-566-2917

Info Phone: 216-566-2902

Cage: DO642

Contractor
SHERWIN-WILLIAMS CO THE SPECIALTY DIV.
6709 SOLON, OH 44139-3908

Telephone: 216-292-7400

Cage: DO642

Ingredients

CALCIUM CARBONATE

CAS: 471-34-1

RTECS: FF9335000

OSHA PEL N/K

ACGIH TLV: N/K


STRONTIUM CHROMATE

CAS: 7789-06-2

RTECS: GB3240000

OSHA PEL C 0.1 MG (CRO3)/M3

ACGIH TLV: 0.0005 MG(CR)/M3

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


CHROMIUM VI

CAS: 18540-29-9

RTECS: GB6262000

OSHA PEL 0.5 MG CR/M3

ACGIH TLV: 0.05 MG CR/M3


POLYAMIDE

CAS: 68082-29-1

OSHA PEL N/K

ACGIH TLV: N/K


XYLENE

CAS: 1330-20-7

RTECS: ZE2100000

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


2-PROPANOL

CAS: 67-63-0

RTECS: NT8050000

OSHA PEL 400 PPM

ACGIH TLV: 400 PPM


1-BUTANOL

CAS: 71-36-3

RTECS: YE1400000

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


METHYL N-PROPYL KETONE

CAS: 107-87-9

RTECS: SA7875000

OSHA PEL 200 PPM

ACGIH TLV: 200 PPM


METHYL ISOAMYL KETONE

CAS: 110-12-3

RTECS: MP3850000

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM


AMIDOAMINE POLYMER

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: IRRITATION OF EYES, SKIN AND
RESPIRATORY SYSTEM. MAY CAUSE NERVOUS SYSTEM DEPRESSION. EXTREME
OVEREXPOSURE MAY RESULT IN UNCONSCIOUSNESS AND POSSIBLY DEATH.
SIGNS AND SYMPTOMS OF OVEREXPOSURE: HEADACHE, DIZZINESS, NAUSEA,
AND LOSS OF COORDINATION ARE INDICATIONS OF EXCESSIVE EXPOSURE TO
VAPORS/SPRAY MISTS. CHRONIC: CHROMATES ARE LISTED BY IARC AND NTP.
STUDIES HAVE ASSOCIATED EXPOSURE TO CH ROMIUM VI COMPOUNDS WITH
INCREASED RISK OF RESPIRATORY CANCER. PROLONGED OVEREXPOSURE TO
SOLVENT INGREDIENTS MAY CAUSE ADVERSE EFFECTS TO LIVER, URINARY AND
REPRODUCTIVE SYSTEMS. REPORTS HAVE ASSOCIAT ED (SIGNS AND SYMPTOMS
OF OVEREXPOSURE)
Explanation of Carcinogenicity:STRONTIUM CHROMATE: IARC MONOGRAPHS
VOLUME 49, PG 49, 1990: GROUP 1. NTP 7TH ANNUAL REPORT ON
CARCINOGENS, 1994: ANTICIPATED TO BE A CARCINOGEN.
Effects of Overexposure:HEALTH HAZARDS ACUTE AND CHRONIC (CONT):
REPEATED AND PROLONGED OVEREXPOSURE TO SOLVENTS WITH PERMANENT
BRAIN AND NERVOUS SYSTEM DAMAGE.
Medical Cond Aggravated by Exposure:MAY CAUSE ALLERGIC SKIN REACTION IN
SUSCEPTIBLE PERSONS.

First Aid

First Aid:INHAL: REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP WARM &
QUIET. SKIN: WASH AREA THOROUGHLY W/SOAP & WATER. REMOVE
CONTAMINATED CLOTHING & LAUNDER BEFORE RE-USE. EYES: FLUSH WITH
LARGE AMOUNTS OF WA TER FOR AT LEAST 15 MINUTES. GET MEDICAL
ATTENTION. INGEST: GET MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:PMCC
Flash Point:=7.8C, 46.F
Lower Limits:1.0%
Upper Limits:12.7%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:NIOSH APPROVED SELF CONTAINED BREATHING
APPARATUS AND FULL PROTECTIVE EQUIPMENT . IF WATER IS USED, FOG
NOZZLES ARE PREFERED. WATER MAY BE USED TO COOL CLOSED CONTAINERS
TO PREVENT PRESSURE BUIL D-UP AND POSS AUTOIGNITION / EXPLOSION
WHEN EXPOSED TO EXTREME HEAT
Unusual Fire/Explosion Hazard:KEEP CONTAINERS TIGHTLY CLSD. ISOLATE
FROM HEAT, ELEC EQUIP, SPKS, & OPEN FLAME. CLSD CNTNRS MAY EXPLODE
WHEN EXPOS TO EXTREME HEAT. APPLIC TO HOT SURFS REQUIRES SPECIAL
PREC. DURING EMERGENCY CONDITI ONS OVEREXP TO DECOMP PRODUCTS MAY
CAUSE HEALTH HAZARDS. SYMPTOMS MAY NOT BE IMMED APPARENT. OBTAIN
MEDICAL ATTENTION.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:USE ONLY WITH ADEQUATE VENTILATION.
AVOID BREATHING VAPORS AND SPRAY MIST. AVOID CONTACT WITH SKIN AND
EYES.
Other Precautions:THIS COATING MAY CONTAIN MATERIALS CLASSIFIED AS
NUISANCE PARTICULATES (LISTED "AS DUST") WHICH MAY BE PRESENT AT
HAZARDOUS LEVELS ONLY DURING SANDING/ABRADING OF DRIED FILM. IF NO
SPECIFIC DUSTS ARE LISTED, APPLICABLE LIMITS FOR NUISANCE DUSTS
ARE: ACGIH TLV: 10 MG/M3 (TOTAL DUST), (TOXICOLOGICAL I NFORMATION)

Exposure Controls

Respiratory Protection:IF PERSONAL EXPOSURE CANNOT BE CONTROLLED BELOW
APPLICABLE LIMITS BY VENTILATION, WEAR PROPERLY FITTED ORGANIC
VAPOR/PARTICULATE RESPIRATOR APPRVD BY NIOSH FOR PROTECTION AGAINST
MATERIALS. WHEN SANDI NG, WIRE BRUSHING, ABRADING, BURNING/WELDING
DRIED FILM, WEAR A PARTICULATE RESPIRATOR APPROVED BY NIOSH FOR
PROTECTION AGAINST NON-VOLATILE MATERIALS.
Ventilation:LOCAL EXHAUST PREFERABLE. GENERAL EXHAUST ACCEPTABLE IF
EXPOS IS MAINTAINED BELOW APPLICABLE EXPOSURE LIMITS. REFER TO OSHA
STDS 1910.94, 1910.107, 1910.108.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER . USE
OF BARRIER CREAM ON EXPOSED SKIN IS RECOMMENDED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MFR TRADE NAME/PART NO: 2.8 VOC CHROMATED EPOXY POLYAMIDE PRIMER PART A
(P&L 72450).

Chemical Properties

Boiling Pt:>81.1C, 178.F
Vapor Pres:OTHER INFO
Vapor Density:HVR/AIR
Spec Gravity:1.80
VOC Pounds/Gallon:348
VOC Grams/Liter:2.91
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:42

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:BY FIRE: CARBON DIOXIDE, CARBON
MONOXIDE, OXIDES OF METALS IN INGREDIENTS.

Disposal

Waste Disposal Methods:WASTE FROM PRODUCT MAY BE HAZARDOUS AS DEFINED
UNDER RCRA 40 CFR 261. WASTE MUST BE TREATED FOR IGNITABILITY TO
DETERMINE APPLICABLE EPA HAZARDOUS WASTE NUMBERS. DO NOT
INCINERATE. DEPRESSURIZE CONTAI NER. DISPOSE OF IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL REGULATIONS REGARDING POLLUTION.

Toxicology

Toxicological Information:N/P. OTHER PRECAUTIONS (CONT): 3 MG/M3
(RESPIRABLE FRACTION); OSHA PEL: 15 MG/M3 (TOTAL DUST), 5 MG/M3
(RESPIRABLE FRACTION). CONTENTS ARE FLAMMABLE. KEEP AWAY FROM
HEAT, SPARKS, AND OPEN FLAM E. DURING USE AND UNTIL ALL VAPORS ARE
GONE: KEEP AREA VENTILATED - DO NOT SMOKE - EXTINGUISH ALL FLAMES,
PILOT LIGHTS, AND HEATERS - TURN OFF STOVES, ELECTRIC TOOLS AND
APPLIANCES, AND ANY OTHER SOUR CES OF IGNITION. CONSULT NFPA CODE.
USE APPROVED BONDING AND GROUNDING PROCEDURES. KEEP CONTAINER
CLOSED WITH COMPLETE AND APPROPRIATE LABELING. DO NOT TAKE
INTERNALLY. KEEP OUT OF REACH OF CHILDREN. (OTHER INFORMATION)

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Regulatory

SARA Title III Information:SARA 313: XYLENE, STRONTIUM CHROMATE.
Federal Regulatory Information:CERCLA: XYLENE, STRONTIUM CHROMATE.